Calculator

Civil & Structural Engineering Uplift check

Overhanging Beam Calculator

28 September 2026 11 min read

Reactions with uplift flag, support moment and SFD/BMD for beams with a tip-loaded overhang plus main-span UDL.

Ra (back)
7.0 kN
upward
Rb (support)
23.0 kN
carries tip load
Moment @ Rb
-15.0 kN·m
hogging
Equilibrium
ΣF = 0 ✓
total 30.0 kN

Live statistics

Back reaction Ra

7.0 kN

upward

Support Rb

23.0 kN

interior support

Support moment

-15.0 kN·m

hogging over Rb

Span moment

6.1 kN·m

main-span sag

Free-body sketch (not to scale). Green = reactions (upward). Red = point load P at position a, amber = UDL intensity w. Negative reaction means uplift — provide hold-down.

Loading plans — pick your design case

Plans load realistic preset forces so estimates match the building use. Your typed values are never overwritten unless you pick a plan.

Unit system
Main span L(m) Help
m

Between supports.

Overhang c(m) Help
m

Past RIGHT support; P at tip.

Tip load P(kN) Help
kN

At overhang tip.

UDL w (main span)(kN/m) Help
kN/m

Include self-weight.

Precision(decimals) Help
decimals

Decimals.

Results update live as you type

How you compare — standard sections

SectionDepth (mm)Mass (kg/m)A (cm²)Iₓ (×10⁶ mm⁴)Sₓ (×10³ mm³)
UB 305×165×40 · Steel I-beam 30440.351.385560
UB 457×191×67 · Steel I-beam 45467.185.52941290
UC 254×254×73 · Steel column 25473.193.1114895
RC 300×500 (C30) · Concrete beam 5003751500312512500
Glulam 140×450 · Timber beam 4502963010634725
SHS 200×200×8 · Hollow section 20047.460.436.9369

Indicative values for scheme design only. Always verify against the manufacturer / code tables (AISC Steel Manual, SCI Blue Book, ACI detailing) before ordering steel or pouring concrete.

Plans & details

Detail

Bearing detail

Padstone sized for max reaction. Check masonry bearing and provide 150 mm min seating.

RCC

Reinforcement sketch

Bottom steel for sagging, top steel at supports for hogging. Extend past inflection + development length.

Uplift

Hold-down where needed

Strap or anchor for any uplift reaction. Size for net factored uplift per ASCE 7.

Typical details for scheme design. Replace placeholders with project drawings (1200×630 JPG or SVG line work in /public/plans/civil/). Do not scale from web images — use figured dimensions.

Design verification checklist

Work through before issuing results — 1/6 verified (17%).

Results

Normal

Back reaction Ra

7.0kN

Upward at back support

Interior reaction Rb

23.0kN

Carries main span + tip load

Moment over Rb

-15.0kN·m

Hogging = −P·c, top steel

Main-span sag

6.1kN·m

Bottom steel design value

Max shear

23.0kN

Peak shear magnitude

Visualizations

Support reactions (kN) — bar = magnitude, amber = uplift (hold-down)

7 kNR1
23 kNR2

Shear force diagram (SFD) — kN vs station (m)

Bending moment diagram (BMD) — kN·m vs station (m); + sagging / − hogging

Formula

Moments about Rb eliminate it and give the back reaction directly; the overhang tip load levers uplift at the far support while piling onto the near one.

Ra = wL/2 − Pc/L | Rb = wL/2 + P(L+c)/L | M over Rb = −P·c

Alternative Form

Uplift when Pc > wL²/2 · Main-span sag ≈ Ra²/2w (UDL-dominated)

Variables

SymbolNameUnitDescription
RaBack reactionkNAt far (left) support; negative = uplift.
RbInterior reactionkNAt support under the overhang root.
MsupSupport momentkN·mHogging over Rb equal to −P·c.
P @ cTip loadkN @ mAt c past the support.
wMain UDLkN/mOn the main span only.
L / cSpan / overhangmMain span and tip length.

Explanation

The overhang is a lever arm c multiplying the tip load against the backspan: Ra = wL/2 − Pc/L goes negative fast, while Rb = wL/2 + P(L+c)/L piles up.

Derivation

ΣM about Rb: Ra·L + P·c − wL·L/2 = 0 gives Ra; ΣF gives Rb. The free-body cut just left of Rb carries moment −P·c from the tip load alone.

Step-by-Step Calculation

Follow each step to understand how the result is calculated from your inputs.

Step 1

Enter main span L and overhang c

Result: Geometry fixed
Step 2

Enter tip load P and main-span UDL w

Result: Loads fixed
Step 3

Read Ra — negative means uplift hold-down

Result: Uplift checked
Step 4

Read Rb for the support post/pad

Result: Support sized
Step 5

Read hogging −P·c for top steel

Result: Root designed
Step 6

Verify Ra + Rb = P + wL

Result: Equilibrium proven
Final Answer
7.0

Worked Examples

See how the calculator works with different scenarios.

Scenario

Balcony beam with planter at tip.

Inputs

L:5 m
c:1.5 m
P:10 kN
w:0

Calculation

Ra = −10·1.5/5 = −3 kN. Rb = 10·6.5/5 = 13 kN. M = −15 kN·m.

Result

Ra = −3 kN uplift, Rb = 13 kN

Interpretation

Back support needs a 3 kN strap; root needs top steel for 15 kN·m factored.

Understanding Your Result

Your Result: Back reaction Ra = 7.0 kN · Interior reaction Rb = 23.0 kN · Moment over Rb = -15.0 kN·m

Typical range: Uplift ≈ P·c/L (10–40% of tip load typical). Root hogging = P·c exactly.

What This Means

Back reaction (often uplift), loaded support reaction, and the hogging root moment are the three numbers that size straps, posts and top steel.

Why It Matters

Overhangs are uplift machines: the tip load levers the far bearing off its seat while overloading the near one. Both failures are sudden and expensive.

Professional Interpretation

Run gravity-only AND 0.9D+1.0W uplift combos; detail the hold-down for the worst net pull with proper embedment and a load path to mass.

Recommendations

  • •Verify equilibrium: reactions sum to total load
  • •Include self-weight in the UDL before issuing numbers
  • •Keep service and factored (1.2D+1.6L) columns separate

Learn — structural behaviour, deeply

A lever with a building on the short end.

1 · The two equations that run every site

ΣF_y = 0

Vertical balance

Upward reactions must equal total downward load. Missing 1 kN here means a 1 kN shear error everywhere downstream.

ΣM = 0

Moment balance

Moments about ANY point must cancel. Take moments about one support to eliminate it and solve the other directly.

ΣF_x = 0

Horizontal balance

Zero for vertical-only loading — but the pin still needs checking once wind, soil or inclined loads appear.

Worked derivation (simply supported, point load): ΣMleft = 0 ⇒ Rb·L − P·a = 0 ⇒ Rb = P·a/L, then ΣFy = 0 ⇒ Ra = P − Rb = P·(L−a)/L. UDL adds w·L/2 per side acting at midspan. That is the entire calculation — everything else is bookkeeping.

2 · Support types — what each one can (and cannot) do

SupportReactionsAllowsWatch out
Roller1 (vertical)Horizontal slide + rotationProvides NO lateral restraint — pair with a pin or bracing.
Pin / hinge2 (vertical + horizontal)Rotation onlyMoment released here — detail the hinge, never weld it rigid by accident.
Fixed / clamped3 (+ moment)Nothing (fully restrained)Attracts large moments; settlement or temperature causes locked-in stress.
Propped cantilever3 (indeterminate ×1)Rotation at propNeeds compatibility (deflection = 0 at prop) — equilibrium alone is not enough.
Continuous (3+ supports)4+ (indeterminate)Rotation over interior piersSolve by superposition / moment distribution / software; reactions shift with stiffness.

3 · Factor-impact table — what moves your reactions most

FactorTypical impactWhy
Load position (a/L)Linear, dominantMoving P toward a support shifts ~100% of P onto it. Ra = P·(L−a)/L — position matters more than span.
UDL intensity (w)∝ w·L totalEach extra 1 kN/m on a 6 m beam adds 3 kN per reaction. Self-weight alone is often 1–5 kN/m on concrete.
Span length (L)∝ L for UDLDoubling L doubles UDL reactions and quadruples UDL moment (wL²/8). Keep spans tight where possible.
Overhang length (c)∝ c/L upliftUplift at the far support = P·c/L. A 2 m overhang with 10 kN on a 5 m span pulls down 4 kN — needs hold-down.
Fixity (pinned → fixed)Redistributes ~10–30%Fixed ends attract moment and shed midspan moment. Never assume fixity you have not detailed.
Support settlement (Δ)0 (det.) / large (indet.)Determinate beams just rotate; continuous/fixed beams develop locked-in moments ≈ 3EIΔ/L².
Dynamic / impact+10–100%Static reactions must be amplified for cranes, machinery, footfall (see ASCE 7 Ch. 4, AISC DG11).
Load combination× 1.2–1.6 (LRFD)1.2D + 1.6L + 0.5(Lr/S/R) governs most beams. Reactions for strength ≠ reactions for service checks.

4 · Code provisions you must cite on drawings

  • ASCE 7 load combinations (LRFD): 1.4D · 1.2D + 1.6L + 0.5(Lr/S/R) · 1.2D + 1.0W + 1.0L … Strength reactions use factored loads; bearing/deflection checks use service (unfactored) loads.
  • ACI 318 (concrete): strength-reduction ϕ = 0.65–0.90; development/lap lengths Ch. 25; one-way shear + punching Ch. 22. Reactions feed directly into Vu ≤ ϕVn.
  • AISC 360 (steel): Ch. F/G/H for moment/shear/combined; bearing at supports per J7–J8; bracing per App. 6. Connection must develop the computed reaction — a beam is only as strong as its seat.
  • Eurocode basis (EN 1990): ULS 1.35G + 1.5Q; SLS G + Q (characteristic). National annexes adjust factors — confirm the project annex.
  • Serviceability (all codes): live-load deflection ≈ L/360 floors, L/240 roofs; total ≈ L/240. Vibration: AISC DG11 / SCI P354 for rhythmic or office floors.

5 · Pro workflow (5 minutes per beam)

  1. Sketch the free-body diagram: every load incl. self-weight, every support, dimensions.
  2. Solve ΣM then ΣF — write both lines on the calc sheet so a checker can follow.
  3. Verify: re-take moments about the OTHER support; residual must be ≈ 0.
  4. Draw shear then moment (reactions are the SFD starting values).
  5. Size the support: bearing stress, padstone, bolt/weld group, foundation pressure.
  6. File: keep the input → reaction → SFD/BMD → support chain on one page.

6 · Field traps (where reactions go wrong)

  • • Forgetting self-weight: a 300×600 concrete beam weighs 4.5 kN/m — on 6 m that is 13.5 kN per support.
  • • Assuming fixity: a “fixed” sketch with two bolts is a pin. Model what you detail.
  • • Ignoring uplift: overhang + wind can reverse a bearing — light roofs lift off.
  • • Mixing factored/service: never compare a factored reaction against an allowable soil pressure.
  • • Point load at the wrong station: 0.5 m error on a 10 kN load swings reactions by P·Δa/L.

7 · The 3-check rule (sign-off standard)

  1. Math check: ΣFy and ΣM both close to zero with project units printed.
  2. Sanity check: reactions sum to total load; heavier side sits under heavier load; UDL symmetry gives Ra ≈ Rb.
  3. Load-path check: every reaction lands on something sized for it — beam → seat → column → footing → soil, no floating numbers.

Practical Tips

  • •Ra + Rb must equal total load — if not, the input (not physics) is wrong
  • •UDL symmetry gives Ra = Rb = wL/2 — use as a 2-second check
  • •Report service kN to 1 decimal for bearings and footings

Common Mistakes

Self-weight omitted
Bundle member kN/m into w first.
Factored reaction checked against soil pressure
Soils take SERVICE loads; keep a separate factored column.
Uplift ignored
Negative R needs a hold-down detail, not a bigger pad.

Assumptions

This calculator makes the following assumptions to provide estimates:

Rigid supports: No settlement or rotation under load.
Small deflections: Geometry unchanged by loading; superposition applies.
Static loading: No impact, vibration or seismic amplification included.

Limitations

Be aware of these limitations when using this calculator:

Determinate unless stated: Continuous and propped cases use the compatibility solution noted in the formula.
Prismatic sections: Constant EI along the span.

Frequently Asked Questions

Answers to common questions about this calculator.

When does the back support lift?
When P·c exceeds wL²/2 worth of stabilizing moment — light backspans with heavy tips. The calculator flags negative Ra automatically.
What resists uplift?
A hold-down strap, anchor bolt or ballast sized for net factored uplift (0.9D + 1.0W). A bigger pad alone does nothing for the wrong direction.
Where is the worst hogging?
Right over the interior support: exactly −P·c from the tip load, plus any UDL continuity effects. Detail top steel there.
Does UDL on the overhang itself matter?
Yes — add it as an equivalent tip load P_eq = w_oh·c at c/2 in this version, or split the run. This page puts UDL on the main span and P at the tip.
How long can the overhang be?
Rule of thumb: keep c ≤ L/3 for floors so service uplift stays manageable; verify deflection at the tip (roughly PcL²/3EI plus rotation effects).
Do I check wind on the overhang?
Always — suction on a canopy overhang reverses with 0.9D + 1.0W and often governs the hold-down, not gravity.
How do I find reactions for a simply supported beam?
Take moments about the left support: Rb = (P·a + w·L·L/2) / L, then Ra = P + w·L − Rb. Always re-check by taking moments about the right support — the residual must be ≈ 0.
What does a negative (downward) reaction mean?
The support must pull DOWN instead of pushing up — net uplift from overhangs, pattern loading or wind. Provide a hold-down strap, anchor or ballast; a gravity-only bearing will lift off.
Do I include the beam self-weight?
Yes, always. A 300×600 mm concrete beam weighs ~4.5 kN/m — on a 6 m span that adds ~13.5 kN per support. Bundle it into the UDL before solving.
Service vs factored loads — which do I report?
Report BOTH in separate columns: service (unfactored D+L) for deflection, bearing, settlement and soil checks; factored LRFD (1.2D + 1.6L) for member strength. Never compare a factored reaction with an allowable soil pressure.
What is the difference between a UDL and a UVL?
A UDL (uniformly distributed load) is constant intensity over a length (kN/m). A UVL (uniformly varying / triangular) runs zero-to-max — e.g. soil or hydrostatic pressure. They integrate differently, so use the matching calculator.
How do I turn a floor area load into a beam line load?
Multiply the area load (kN/m²) by the tributary width (m) draining to the beam: line load = area load × tributary width. Add the beam self-weight, partitions and finishes first.
What is tributary area?
The floor/roof area whose load flows to one member — bounded by halfway lines to adjacent members. Tributary area × area load = the point/line load that member must carry.
Which load combination usually governs a beam?
For strength: 1.2D + 1.6L (+ 0.5 for roof live/snow/rain) per ASCE 7 LRFD. Service D+L governs deflection and bearings; 0.9D + 1.0W governs uplift and overturning.
LRFD vs ASD — does it change the reactions?
No — equilibrium is the same. The design PHILOSOPHY differs: LRFD factors loads up (1.2D+1.6L) against factored resistance (ϕRn); ASD keeps service loads against allowable stresses (Rn/Ω). Keep the two systems in separate columns.
Pin, roller or fixed — how do I choose the support model?
Model what you DETAIL. Masonry/steel seats and two-bolt end plates are pins (moment released); moment frames, welded rigid joints and well-anchored cantilevers earn fixity. When in doubt, the pinned assumption is conservative for midspan moment but NOT for uplift.
What deflection limits apply to beams?
Typical code limits: live-load deflection L/360 for floors (L/240 roofs), total-load L/240, cantilevers 2L/360-ish per IBC Table 1604.3. Always check under SERVICE loads with the correct (cracked, long-term) stiffness.
How do I convert kN ↔ kips and m ↔ ft?
1 kN = 0.2248 kips (1 kip = 4.448 kN); 1 m = 3.2808 ft. Moments: 1 kN·m = 0.7376 kip·ft. Every calculator on this site has an SI/Imperial toggle that converts all displayed values.
Shear vs bending moment — which sizes what?
Shear sizes stirrups/webs and connections (V ≤ ϕVn); bending moment sizes flexural steel and the section (M ≤ ϕMn via section modulus S: stress = M/S). Deflection is governed by stiffness EI, a third independent check.
Where does the maximum moment occur?
Where shear crosses zero: under a midspan point load, or at x = R/w under UDL (span moment = R·x − w·x²/2). On continuous beams also check the hogging peaks OVER interior supports — they often govern.
What is section modulus and how do I use it?
S = I/c (mm³): the geometric bending efficiency of a section. Bending stress = M/S; required S = factored moment / allowable (or design) stress. Compare against the standard-section table on each page.
How do I quickly check a steel beam?
Three checks per AISC 360: bending (Ch. F incl. lateral-torsional buckling over the unbraced length), shear (Ch. G), and deflection (L/360). Then verify the connection develops the end reaction.
How do I quickly check a concrete beam?
Flexure per ACI 318: ϕMn = ϕ·As·fy·(d − a/2) with ϕ = 0.9 (tension-controlled); one-way shear Vc + Vs (Ch. 22); deflection via minimum thickness or direct computation with cracked stiffness and long-term multiplier.
What is development length and why does it matter?
The embedment needed for a bar to reach yield (ld, ACI 318 Ch. 25). A perfectly computed moment capacity is worthless if the bar pulls out — extend bars past inflection points and hook or develop them at supports.
How do I check bearing stress under a support?
Bearing stress = reaction / (bearing length × width) ≤ allowable (masonry ≈ 0.25–0.4·f′m, concrete per ACI 22.8, steel per AISC J8). If it fails, lengthen the bearing or add a padstone/spreader plate.
Hold-down or bigger pad — which fixes uplift?
Only a hold-down (strap, anchor, dead weight) fixes uplift — a bigger pad just spreads a force acting the wrong way. Size the anchor for net factored uplift (0.9D + 1.0W) with proper embedment.
Which codes do these calculators follow?
Workflows cite ACI 318 (concrete), AISC 360 (steel), ASCE 7 (loads + combinations), IBC (deflection, occupancy loads) and Eurocode equivalents. Always confirm the edition and annex your project is permitted under.
How accurate are these calculators?
Scheme-stage accuracy from closed-form statics with stated assumptions (rigid supports, prismatic sections, static loads). Use them for sizing, checking and tender estimates — final permit/shop drawings need a licensed engineer and project-specific analysis.
Can I print, copy or share results?
Yes — every page has print, copy-link and share actions in the hero banner, and results render in a printable dashboard. Paste the equilibrium line (ΣR vs total load) onto your calc sheet as the proof.
Do I still need a structural engineer?
For anything that gets built: yes. Software and calculators don’t carry liability, don’t visit site, and don’t know your soil, wind exposure or buildability constraints. Use these tools to brief and check your engineer, not replace them.
How does wind create uplift on beams and roofs?
Suction on leeward slopes/overhangs pulls upward; the net combination 0.9D + 1.0W (ASCE 7) often reverses light end reactions. Run it explicitly — gravity-only models hide the governing hold-down case.

Related Calculators

Explore more calculators related to this topic.

Glossary

Technical terms used in mortgage calculations explained in plain language.

Reaction
Force (or moment) a support exerts on a member to maintain static equilibrium (ΣF = 0, ΣM = 0).
Simply supported
Beam on one pin + one roller. Resists vertical load; allows rotation and (at roller) horizontal movement.
Fixed support
Clamped end resisting force AND moment; prevents rotation. Used in cantilevers and fixed frames.
UDL / UVL
Uniformly distributed load (constant kN/m) vs. uniformly varying load (triangular, zero-to-max).
Tributary area
Floor/roof area whose load drains to one member. Line load = area load × tributary width.
Factored load
Service load × LRFD load factor (e.g. 1.2D + 1.6L) for strength design per ASCE 7.
Serviceability
Deflection, cracking and vibration limits under day-to-day (unfactored) loads.
Uplift
Net downward-hold requirement: a negative (downward-pulling) reaction, common on overhangs.

Authoritative References

Trusted sources and standards referenced by this calculator.

Applicable Standards

ACI 318 — Building Code Requirements for Structural ConcreteAISC 360 — Specification for Structural Steel BuildingsASCE 7 — Minimum Design Loads and Associated CriteriaEurocode 2 (EN 1992) — Design of Concrete StructuresEurocode 3 (EN 1993) — Design of Steel StructuresIBC — International Building Code (structural chapters 16–23)

Was This Calculator Helpful?

Page Information

Last Updated:

2026-09-28

Version:

2.0.0

License:

Free to use for educational and professional purposes.