Calculator

Civil & Structural Engineering square · emin

Square Column Calculator

28 September 2026 11 min read

Square column axial capacity with ACI 318 minimum eccentricity check.

phi Pn
2423 kN
util 0.62

Live statistics

phi Pn

2423 kN

e act

40 mm

e min

27.0 mm

Unit system
Side h(mm) Help
mm

Square side.

Factored load Pu(kN) Help
kN

Factored axial demand.

Factored moment Mu(kN·m) Help
kN·m

Factored moment demand.

Concrete fc(MPa) Help
MPa

Cylinder strength.

Steel fy(MPa) Help
MPa

Rebar yield strength.

Steel percentage(%) Help
%

Ast over Ag in percent.

Results update live as you type

How you compare — standard sections

SectionDepth (mm)Mass (kg/m)A (cm²)Iₓ (×10⁶ mm⁴)Sₓ (×10³ mm³)
UB 305×165×40 · Steel I-beam 30440.351.385560
UB 457×191×67 · Steel I-beam 45467.185.52941290
UC 254×254×73 · Steel column 25473.193.1114895
RC 300×500 (C30) · Concrete beam 5003751500312512500
Glulam 140×450 · Timber beam 4502963010634725
SHS 200×200×8 · Hollow section 20047.460.436.9369

Indicative values for scheme design only. Always verify against the manufacturer / code tables (AISC Steel Manual, SCI Blue Book, ACI detailing) before ordering steel or pouring concrete.

Plans & details

Detail

Column section detail

Cover, ties and bar layout per ACI 318. Extend bars past the joint plus development length.

Path

Load path sketch

Slab to beam to column to footing. Verify tributary areas before issuing numbers.

Check

Site verification

Confirm concrete strength, cover and compaction against drawings and test records.

Typical details for scheme design. Replace placeholders with project drawings (1200×630 JPG or SVG line work in /public/plans/civil/). Do not scale from web images — use figured dimensions.

Design verification checklist

Work through before issuing results — 1/6 verified (17%).

Results

Optimal

Design capacity phi Pn

2423kN

Tied maximum axial strength.

Actual eccentricity

40mm

Mu over Pu against the minimum.

Minimum eccentricity

27.0mm

15 mm plus 0.03 h per ACI 318.

Visualizations

Results Overview

2,423kNDesign capacity phi Pn
40kNActual eccentricity
27kNMinimum eccentricity

Formula

Square squash capacity plus the ACI 318 minimum eccentricity rule that forces every column to carry at least a nominal moment.

Ag = h² | Pn tied pair as axial page | e,act = Mu/Pu x 1000 | e,min = 15 + 0.03 h

Alternative Form

Design for max(e,act, e,min) times Pu as moment

Variables

SymbolNameUnitDescription
phi PnDesign axialkNTied capped strength of the square.
e,actActual eccentricitymmDemand eccentricity.
e,minMinimum eccentricitymmCode floor on eccentricity.

Explanation

Tied squash capacity plus the ACI 318 minimum eccentricity of 15 mm plus 3 percent of depth.

Derivation

Concentric squash capacity per the axial formula with the ACI 318 tied cap, paired with the minimum-eccentricity clause for accidental out-of-plumb and load offset.

Step-by-Step Calculation

Follow each step to understand how the result is calculated from your inputs.

Step 1

Enter side h, Pu, Mu, materials and steel

Result: Data fixed
Step 2

Read phi Pn and axial utilisation

Result: Strength issued
Step 3

Compare actual eccentricity with minimum

Result: Eccentricity verdict issued
Final Answer
2423

Worked Examples

See how the calculator works with different scenarios.

Scenario

Pu 1500 kN, Mu 60 kN m, 2 percent steel.

Inputs

h:400
Pu:1500
Mu:60
fc:25
fy:415
steelPct:2

Calculation

Ag is 160000 mm2 and Pn is 4660 kN, so phi Pn is 2423 kN. Actual eccentricity is 60 / 1500 x 1000 = 40 mm against a minimum of 15 + 0.03 x 400 = 27 mm.

Result

phi Pn = 2423 kN, e 40 mm over emin 27 mm

Interpretation

Axial utilisation 0.62 with real moment above the minimum; detail for combined load.

Understanding Your Result

Your Result: Design capacity phi Pn = 2423 kN · Actual eccentricity = 40 mm · Minimum eccentricity = 27.0 mm

Typical range: 400 to 500 mm squares carry 1500 to 2500 kN factored in offices.

What This Means

Axial headroom plus whether real eccentricity clears the code minimum.

Why It Matters

Ignoring minimum moment under-designs nominally concentric columns.

Professional Interpretation

Always report which eccentricity governed, actual or minimum, beside capacity.

Recommendations

  • •Check slenderness before trusting short-column capacity
  • •Keep service and factored (1.2D + 1.6L) columns separate
  • •Verify one line by hand per schedule

Learn — structural behaviour, deeply

Squares with an honesty floor on moment.

1 · The two equations that run every site

ΣF_y = 0

Vertical balance

Upward reactions must equal total downward load. Missing 1 kN here means a 1 kN shear error everywhere downstream.

ΣM = 0

Moment balance

Moments about ANY point must cancel. Take moments about one support to eliminate it and solve the other directly.

ΣF_x = 0

Horizontal balance

Zero for vertical-only loading — but the pin still needs checking once wind, soil or inclined loads appear.

Worked derivation (simply supported, point load): ΣMleft = 0 ⇒ Rb·L − P·a = 0 ⇒ Rb = P·a/L, then ΣFy = 0 ⇒ Ra = P − Rb = P·(L−a)/L. UDL adds w·L/2 per side acting at midspan. That is the entire calculation — everything else is bookkeeping.

2 · Support types — what each one can (and cannot) do

SupportReactionsAllowsWatch out
Roller1 (vertical)Horizontal slide + rotationProvides NO lateral restraint — pair with a pin or bracing.
Pin / hinge2 (vertical + horizontal)Rotation onlyMoment released here — detail the hinge, never weld it rigid by accident.
Fixed / clamped3 (+ moment)Nothing (fully restrained)Attracts large moments; settlement or temperature causes locked-in stress.
Propped cantilever3 (indeterminate ×1)Rotation at propNeeds compatibility (deflection = 0 at prop) — equilibrium alone is not enough.
Continuous (3+ supports)4+ (indeterminate)Rotation over interior piersSolve by superposition / moment distribution / software; reactions shift with stiffness.

3 · Factor-impact table — what moves your reactions most

FactorTypical impactWhy
Load position (a/L)Linear, dominantMoving P toward a support shifts ~100% of P onto it. Ra = P·(L−a)/L — position matters more than span.
UDL intensity (w)∝ w·L totalEach extra 1 kN/m on a 6 m beam adds 3 kN per reaction. Self-weight alone is often 1–5 kN/m on concrete.
Span length (L)∝ L for UDLDoubling L doubles UDL reactions and quadruples UDL moment (wL²/8). Keep spans tight where possible.
Overhang length (c)∝ c/L upliftUplift at the far support = P·c/L. A 2 m overhang with 10 kN on a 5 m span pulls down 4 kN — needs hold-down.
Fixity (pinned → fixed)Redistributes ~10–30%Fixed ends attract moment and shed midspan moment. Never assume fixity you have not detailed.
Support settlement (Δ)0 (det.) / large (indet.)Determinate beams just rotate; continuous/fixed beams develop locked-in moments ≈ 3EIΔ/L².
Dynamic / impact+10–100%Static reactions must be amplified for cranes, machinery, footfall (see ASCE 7 Ch. 4, AISC DG11).
Load combination× 1.2–1.6 (LRFD)1.2D + 1.6L + 0.5(Lr/S/R) governs most beams. Reactions for strength ≠ reactions for service checks.

4 · Code provisions you must cite on drawings

  • ASCE 7 load combinations (LRFD): 1.4D · 1.2D + 1.6L + 0.5(Lr/S/R) · 1.2D + 1.0W + 1.0L … Strength reactions use factored loads; bearing/deflection checks use service (unfactored) loads.
  • ACI 318 (concrete): strength-reduction ϕ = 0.65–0.90; development/lap lengths Ch. 25; one-way shear + punching Ch. 22. Reactions feed directly into Vu ≤ ϕVn.
  • AISC 360 (steel): Ch. F/G/H for moment/shear/combined; bearing at supports per J7–J8; bracing per App. 6. Connection must develop the computed reaction — a beam is only as strong as its seat.
  • Eurocode basis (EN 1990): ULS 1.35G + 1.5Q; SLS G + Q (characteristic). National annexes adjust factors — confirm the project annex.
  • Serviceability (all codes): live-load deflection ≈ L/360 floors, L/240 roofs; total ≈ L/240. Vibration: AISC DG11 / SCI P354 for rhythmic or office floors.

5 · Pro workflow (5 minutes per beam)

  1. Sketch the free-body diagram: every load incl. self-weight, every support, dimensions.
  2. Solve ΣM then ΣF — write both lines on the calc sheet so a checker can follow.
  3. Verify: re-take moments about the OTHER support; residual must be ≈ 0.
  4. Draw shear then moment (reactions are the SFD starting values).
  5. Size the support: bearing stress, padstone, bolt/weld group, foundation pressure.
  6. File: keep the input → reaction → SFD/BMD → support chain on one page.

6 · Field traps (where reactions go wrong)

  • • Forgetting self-weight: a 300×600 concrete beam weighs 4.5 kN/m — on 6 m that is 13.5 kN per support.
  • • Assuming fixity: a “fixed” sketch with two bolts is a pin. Model what you detail.
  • • Ignoring uplift: overhang + wind can reverse a bearing — light roofs lift off.
  • • Mixing factored/service: never compare a factored reaction against an allowable soil pressure.
  • • Point load at the wrong station: 0.5 m error on a 10 kN load swings reactions by P·Δa/L.

7 · The 3-check rule (sign-off standard)

  1. Math check: ΣFy and ΣM both close to zero with project units printed.
  2. Sanity check: reactions sum to total load; heavier side sits under heavier load; UDL symmetry gives Ra ≈ Rb.
  3. Load-path check: every reaction lands on something sized for it — beam → seat → column → footing → soil, no floating numbers.

Practical Tips

  • •Split dead vs live early — factoring depends on it
  • •Include self-weight; concrete often dominates
  • •Report service values to 1 decimal for bearings and footings

Common Mistakes

Service load checked against factored capacity
Keep a service column (settlement, soil, deflection) and a factored column (strength) side by side.
Self-weight omitted
Add member weight into the total first.
Wrong units in one term
Convert everything to the page unit system before combining terms.

Assumptions

This calculator makes the following assumptions to provide estimates:

Static gravity loading: No impact, vibration or seismic amplification unless the page applies one.
Nominal material properties: Code-grade materials per project data; confirm lightweight or high-strength cases.
Scheme-level accuracy: Closed-form code clauses for preliminary and check calculations.

Limitations

Be aware of these limitations when using this calculator:

Verify supports and pattern: Pattern loading, continuity and support settlement need their own runs.
Confirm local code values: Loads, factors and minimums vary by jurisdiction.

Frequently Asked Questions

Answers to common questions about this calculator.

Why a minimum eccentricity?
Real columns are never perfectly concentric; the code floor covers construction tolerance and load offset.
What if actual is below minimum?
Design the column for the minimum moment of Pu times e,min.
Why squares?
Equal stiffness both ways suits interior grids with similar spans each direction.
Is this a final design?
No, it is a preliminary check per ACI 318. A licensed engineer must confirm final design.
How do I find reactions for a simply supported beam?
Take moments about the left support: Rb = (P·a + w·L·L/2) / L, then Ra = P + w·L − Rb. Always re-check by taking moments about the right support — the residual must be ≈ 0.
What does a negative (downward) reaction mean?
The support must pull DOWN instead of pushing up — net uplift from overhangs, pattern loading or wind. Provide a hold-down strap, anchor or ballast; a gravity-only bearing will lift off.
Do I include the beam self-weight?
Yes, always. A 300×600 mm concrete beam weighs ~4.5 kN/m — on a 6 m span that adds ~13.5 kN per support. Bundle it into the UDL before solving.
Service vs factored loads — which do I report?
Report BOTH in separate columns: service (unfactored D+L) for deflection, bearing, settlement and soil checks; factored LRFD (1.2D + 1.6L) for member strength. Never compare a factored reaction with an allowable soil pressure.
What is the difference between a UDL and a UVL?
A UDL (uniformly distributed load) is constant intensity over a length (kN/m). A UVL (uniformly varying / triangular) runs zero-to-max — e.g. soil or hydrostatic pressure. They integrate differently, so use the matching calculator.
How do I turn a floor area load into a beam line load?
Multiply the area load (kN/m²) by the tributary width (m) draining to the beam: line load = area load × tributary width. Add the beam self-weight, partitions and finishes first.
What is tributary area?
The floor/roof area whose load flows to one member — bounded by halfway lines to adjacent members. Tributary area × area load = the point/line load that member must carry.
Which load combination usually governs a beam?
For strength: 1.2D + 1.6L (+ 0.5 for roof live/snow/rain) per ASCE 7 LRFD. Service D+L governs deflection and bearings; 0.9D + 1.0W governs uplift and overturning.
LRFD vs ASD — does it change the reactions?
No — equilibrium is the same. The design PHILOSOPHY differs: LRFD factors loads up (1.2D+1.6L) against factored resistance (ϕRn); ASD keeps service loads against allowable stresses (Rn/Ω). Keep the two systems in separate columns.
Pin, roller or fixed — how do I choose the support model?
Model what you DETAIL. Masonry/steel seats and two-bolt end plates are pins (moment released); moment frames, welded rigid joints and well-anchored cantilevers earn fixity. When in doubt, the pinned assumption is conservative for midspan moment but NOT for uplift.
What deflection limits apply to beams?
Typical code limits: live-load deflection L/360 for floors (L/240 roofs), total-load L/240, cantilevers 2L/360-ish per IBC Table 1604.3. Always check under SERVICE loads with the correct (cracked, long-term) stiffness.
How do I convert kN ↔ kips and m ↔ ft?
1 kN = 0.2248 kips (1 kip = 4.448 kN); 1 m = 3.2808 ft. Moments: 1 kN·m = 0.7376 kip·ft. Every calculator on this site has an SI/Imperial toggle that converts all displayed values.
Shear vs bending moment — which sizes what?
Shear sizes stirrups/webs and connections (V ≤ ϕVn); bending moment sizes flexural steel and the section (M ≤ ϕMn via section modulus S: stress = M/S). Deflection is governed by stiffness EI, a third independent check.
Where does the maximum moment occur?
Where shear crosses zero: under a midspan point load, or at x = R/w under UDL (span moment = R·x − w·x²/2). On continuous beams also check the hogging peaks OVER interior supports — they often govern.
What is section modulus and how do I use it?
S = I/c (mm³): the geometric bending efficiency of a section. Bending stress = M/S; required S = factored moment / allowable (or design) stress. Compare against the standard-section table on each page.
How do I quickly check a steel beam?
Three checks per AISC 360: bending (Ch. F incl. lateral-torsional buckling over the unbraced length), shear (Ch. G), and deflection (L/360). Then verify the connection develops the end reaction.
How do I quickly check a concrete beam?
Flexure per ACI 318: ϕMn = ϕ·As·fy·(d − a/2) with ϕ = 0.9 (tension-controlled); one-way shear Vc + Vs (Ch. 22); deflection via minimum thickness or direct computation with cracked stiffness and long-term multiplier.
What is development length and why does it matter?
The embedment needed for a bar to reach yield (ld, ACI 318 Ch. 25). A perfectly computed moment capacity is worthless if the bar pulls out — extend bars past inflection points and hook or develop them at supports.

Related Calculators

Explore more calculators related to this topic.

Glossary

Technical terms used in mortgage calculations explained in plain language.

Reaction
Force (or moment) a support exerts on a member to maintain static equilibrium (ΣF = 0, ΣM = 0).
Simply supported
Beam on one pin + one roller. Resists vertical load; allows rotation and (at roller) horizontal movement.
Fixed support
Clamped end resisting force AND moment; prevents rotation. Used in cantilevers and fixed frames.
UDL / UVL
Uniformly distributed load (constant kN/m) vs. uniformly varying load (triangular, zero-to-max).
Tributary area
Floor/roof area whose load drains to one member. Line load = area load × tributary width.
Factored load
Service load × LRFD load factor (e.g. 1.2D + 1.6L) for strength design per ASCE 7.
Serviceability
Deflection, cracking and vibration limits under day-to-day (unfactored) loads.
Uplift
Net downward-hold requirement: a negative (downward-pulling) reaction, common on overhangs.

Authoritative References

Trusted sources and standards referenced by this calculator.

Applicable Standards

ACI 318 — Building Code Requirements for Structural ConcreteAISC 360 — Specification for Structural Steel BuildingsASCE 7 — Minimum Design Loads and Associated CriteriaEurocode 2 (EN 1992) — Design of Concrete StructuresEurocode 3 (EN 1993) — Design of Steel StructuresIBC — International Building Code (structural chapters 16–23)

Was This Calculator Helpful?

Page Information

Last Updated:

2026-09-28

Version:

2.0.0

License:

Free to use for educational and professional purposes.