Calculator
Torsional Constant Calculator
Torsion constant J for circular, pipe, rectangular and I-type open sections.
- J
- 44.55 ×10⁶mm⁴
- Exact hollow circle.
- Law
- TL/GJ
- twist
- Stress
- Tt/J
- open sections
- Family
- pipe
- basis
Live statistics
44.55 ×10⁶ mm⁴
Exact hollow circle.
pipe
thin-wall basis
φ = TL/GJ
St Venant (free warping)
τ = Tt/J
max at thickest ply
Schematic only — not to scale. Dimensions follow the inputs below.
Diameter, outer D, short side b, or pre-sum Σbt³.
Inner d, thickness t, or long side h.
Rectangle long side (rect mode).
Decimals.
How you compare — standard sections
| Section | Depth (mm) | Mass (kg/m) | A (cm²) | Iₓ (×10⁶ mm⁴) | Sₓ (×10³ mm³) |
|---|---|---|---|---|---|
| UB 305×165×40 · Steel I-beam | 304 | 40.3 | 51.3 | 85 | 560 |
| UB 457×191×67 · Steel I-beam | 454 | 67.1 | 85.5 | 294 | 1290 |
| UC 254×254×73 · Steel column | 254 | 73.1 | 93.1 | 114 | 895 |
| RC 300×500 (C30) · Concrete beam | 500 | 375 | 1500 | 3125 | 12500 |
| Glulam 140×450 · Timber beam | 450 | 29 | 630 | 1063 | 4725 |
| SHS 200×200×8 · Hollow section | 200 | 47.4 | 60.4 | 36.9 | 369 |
Indicative values for scheme design only. Always verify against the manufacturer / code tables (AISC Steel Manual, SCI Blue Book, ACI detailing) before ordering steel or pouring concrete.
Plans & details
Section sketch
Dimensioned cross-section with centroid and axes. Verify b/h/t against drawings before issuing.
Bar layout / rolling
For RC: cover, bar positions and crack basis. For steel: rolling direction and weld access.
Connection zones
Holes, copes and welds deduct from gross — use nett properties at connections.
Typical details for scheme design. Replace placeholders with project drawings (1200×630 JPG or SVG line work in /public/plans/civil/). Do not scale from web images — use figured dimensions.
Design verification checklist
Work through before issuing results — 1/6 verified (17%).
Results
Torsional constant J
44.55×10⁶ mm⁴
Exact hollow circle.
1/GJ
φ = TL/GJ with shear modulus G
Tt/J
Peak at thickest rectangle (open)
pipe
Exact hollow circle.
Visualizations
Torsion constant (×10⁶ mm⁴)
Formula
St Venant torsion: circles exact, thin rectangles approximate, open built-ups summed strip by strip.
Alternative Form
Variables
| Symbol | Name | Unit | Description |
|---|---|---|---|
| J | Torsion constant | mm⁴ | Warps-free torsional geometry. |
| T | Torque | kN·m | Applied twisting moment. |
| G | Shear modulus | GPa | Steel ~79, concrete ~12–15. |
| t | Thickness | mm | Peak stress at thickest ply. |
Explanation
J: πD⁴/32 closed-exact, b³h/3-form open-approx — the St Venant geometry behind φ = TL/GJ and τ ≈ Tt/J.
Derivation
Membrane analogy: narrow strips carry shear flow ∝ thickness; summing bt³/3 over plies approximates open J. Closed tubes use Bredt (see box/pipe pages for exact).
Step-by-Step Calculation
Follow each step to understand how the result is calculated from your inputs.
Pick the family closest to your section
Enter diameters or b/t strips
Read St Venant J
Apply φ = TL/GJ for twist
Apply τ ≈ Tt/J at thickest ply
Add warping restraint where ends fix
Worked Examples
See how the calculator works with different scenarios.
Scenario
D = 200, d = 184.
Inputs
Calculation
J = π(1.6e9 − 1.146e9)/32 = 44.6e6 mm⁴.
Result
J ≈ 44.6 ×10⁶ mm⁴
Interpretation
Closed tube: full J active with free warping — efficient.
Understanding Your Result
Your Result: Torsional constant J = 44.55 ×10⁶ mm⁴ · Twist per unit torque-length = 1/GJ · Stress rule = Tt/J
Typical range: Pipes/boxes: tens of ×10⁶ mm⁴; open strips: tenths to few ×10⁶. Two orders apart for the same steel weight.
What This Means
The warping-free torsional stiffness geometry with the twist and stress laws that use it.
Why It Matters
Spandrel and edge beams twist under unbalanced load; J decides whether rotation cracks finishes or redistributes safely.
Professional Interpretation
State free vs restrained basis. For open sections with fixed ends, combine GJ with E·Cw warping before clearing rotations.
Recommendations
- •Verify dimensions against the drawing before issuing properties
- •Use gross properties for analysis; cracked/nett for checks as codes require
- •Compare required S/I against the standard-section table below
Learn — structural behaviour, deeply
Twist has a constant.
1 · The two equations that run every site
ΣF_y = 0
Vertical balance
Upward reactions must equal total downward load. Missing 1 kN here means a 1 kN shear error everywhere downstream.
ΣM = 0
Moment balance
Moments about ANY point must cancel. Take moments about one support to eliminate it and solve the other directly.
ΣF_x = 0
Horizontal balance
Zero for vertical-only loading — but the pin still needs checking once wind, soil or inclined loads appear.
2 · Support types — what each one can (and cannot) do
| Support | Reactions | Allows | Watch out |
|---|---|---|---|
| Roller | 1 (vertical) | Horizontal slide + rotation | Provides NO lateral restraint — pair with a pin or bracing. |
| Pin / hinge | 2 (vertical + horizontal) | Rotation only | Moment released here — detail the hinge, never weld it rigid by accident. |
| Fixed / clamped | 3 (+ moment) | Nothing (fully restrained) | Attracts large moments; settlement or temperature causes locked-in stress. |
| Propped cantilever | 3 (indeterminate ×1) | Rotation at prop | Needs compatibility (deflection = 0 at prop) — equilibrium alone is not enough. |
| Continuous (3+ supports) | 4+ (indeterminate) | Rotation over interior piers | Solve by superposition / moment distribution / software; reactions shift with stiffness. |
3 · Factor-impact table — what moves your reactions most
| Factor | Typical impact | Why |
|---|---|---|
| Load position (a/L) | Linear, dominant | Moving P toward a support shifts ~100% of P onto it. Ra = P·(L−a)/L — position matters more than span. |
| UDL intensity (w) | ∝ w·L total | Each extra 1 kN/m on a 6 m beam adds 3 kN per reaction. Self-weight alone is often 1–5 kN/m on concrete. |
| Span length (L) | ∝ L for UDL | Doubling L doubles UDL reactions and quadruples UDL moment (wL²/8). Keep spans tight where possible. |
| Overhang length (c) | ∝ c/L uplift | Uplift at the far support = P·c/L. A 2 m overhang with 10 kN on a 5 m span pulls down 4 kN — needs hold-down. |
| Fixity (pinned → fixed) | Redistributes ~10–30% | Fixed ends attract moment and shed midspan moment. Never assume fixity you have not detailed. |
| Support settlement (Δ) | 0 (det.) / large (indet.) | Determinate beams just rotate; continuous/fixed beams develop locked-in moments ≈ 3EIΔ/L². |
| Dynamic / impact | +10–100% | Static reactions must be amplified for cranes, machinery, footfall (see ASCE 7 Ch. 4, AISC DG11). |
| Load combination | × 1.2–1.6 (LRFD) | 1.2D + 1.6L + 0.5(Lr/S/R) governs most beams. Reactions for strength ≠ reactions for service checks. |
4 · Code provisions you must cite on drawings
- ASCE 7 load combinations (LRFD): 1.4D · 1.2D + 1.6L + 0.5(Lr/S/R) · 1.2D + 1.0W + 1.0L … Strength reactions use factored loads; bearing/deflection checks use service (unfactored) loads.
- ACI 318 (concrete): strength-reduction ϕ = 0.65–0.90; development/lap lengths Ch. 25; one-way shear + punching Ch. 22. Reactions feed directly into Vu ≤ ϕVn.
- AISC 360 (steel): Ch. F/G/H for moment/shear/combined; bearing at supports per J7–J8; bracing per App. 6. Connection must develop the computed reaction — a beam is only as strong as its seat.
- Eurocode basis (EN 1990): ULS 1.35G + 1.5Q; SLS G + Q (characteristic). National annexes adjust factors — confirm the project annex.
- Serviceability (all codes): live-load deflection ≈ L/360 floors, L/240 roofs; total ≈ L/240. Vibration: AISC DG11 / SCI P354 for rhythmic or office floors.
5 · Pro workflow (5 minutes per beam)
- Sketch the free-body diagram: every load incl. self-weight, every support, dimensions.
- Solve ΣM then ΣF — write both lines on the calc sheet so a checker can follow.
- Verify: re-take moments about the OTHER support; residual must be ≈ 0.
- Draw shear then moment (reactions are the SFD starting values).
- Size the support: bearing stress, padstone, bolt/weld group, foundation pressure.
- File: keep the input → reaction → SFD/BMD → support chain on one page.
6 · Field traps (where reactions go wrong)
- • Forgetting self-weight: a 300×600 concrete beam weighs 4.5 kN/m — on 6 m that is 13.5 kN per support.
- • Assuming fixity: a “fixed” sketch with two bolts is a pin. Model what you detail.
- • Ignoring uplift: overhang + wind can reverse a bearing — light roofs lift off.
- • Mixing factored/service: never compare a factored reaction against an allowable soil pressure.
- • Point load at the wrong station: 0.5 m error on a 10 kN load swings reactions by P·Δa/L.
7 · The 3-check rule (sign-off standard)
- Math check: ΣFy and ΣM both close to zero with project units printed.
- Sanity check: reactions sum to total load; heavier side sits under heavier load; UDL symmetry gives Ra ≈ Rb.
- Load-path check: every reaction lands on something sized for it — beam → seat → column → footing → soil, no floating numbers.
Practical Tips
- •Depth beats width: I ∝ h³, S ∝ h², A ∝ h — deepen before widening
- •State the basis: gross, nett, cracked or transformed
- •Cross-check S_req = M/σ against the table below
Common Mistakes
Assumptions
This calculator makes the following assumptions to provide estimates:
Limitations
Be aware of these limitations when using this calculator:
Frequently Asked Questions
Answers to common questions about this calculator.
J vs polar moment?
Open vs closed?
Restrained warping?
Peak stress location?
Units of GJ?
Concrete beams in torsion?
What is section modulus and how do I use it?
How do I quickly check a steel beam?
How do I quickly check a concrete beam?
Shear vs bending moment — which sizes what?
Where does the maximum moment occur?
How do I convert kN ↔ kips and m ↔ ft?
Which codes do these calculators follow?
How accurate are these calculators?
Can I print, copy or share results?
Do I still need a structural engineer?
What is development length and why does it matter?
How do I check bearing stress under a support?
What deflection limits apply to beams?
LRFD vs ASD — does it change the reactions?
Which load combination usually governs a beam?
Service vs factored loads — which do I report?
Pin, roller or fixed — how do I choose the support model?
Hold-down or bigger pad — which fixes uplift?
How does wind create uplift on beams and roofs?
How do I allow for impact and vibration?
How do I find reactions for a simply supported beam?
What does a negative (downward) reaction mean?
Do I include the beam self-weight?
What is the difference between a UDL and a UVL?
How do I turn a floor area load into a beam line load?
Related Calculators
Explore more calculators related to this topic.
Glossary
Technical terms used in mortgage calculations explained in plain language.
- Reaction
- Force (or moment) a support exerts on a member to maintain static equilibrium (ΣF = 0, ΣM = 0).
- Simply supported
- Beam on one pin + one roller. Resists vertical load; allows rotation and (at roller) horizontal movement.
- Fixed support
- Clamped end resisting force AND moment; prevents rotation. Used in cantilevers and fixed frames.
- UDL / UVL
- Uniformly distributed load (constant kN/m) vs. uniformly varying load (triangular, zero-to-max).
- Tributary area
- Floor/roof area whose load drains to one member. Line load = area load × tributary width.
- Factored load
- Service load × LRFD load factor (e.g. 1.2D + 1.6L) for strength design per ASCE 7.
- Serviceability
- Deflection, cracking and vibration limits under day-to-day (unfactored) loads.
- Uplift
- Net downward-hold requirement: a negative (downward-pulling) reaction, common on overhangs.
Authoritative References
Trusted sources and standards referenced by this calculator.
Applicable Standards
Was This Calculator Helpful?
Page Information
2026-09-28
2.0.0
Free to use for educational and professional purposes.