Calculator

Civil & Structural Engineering Z · point symmetric

Z-Section Properties Calculator

28 September 2026 9 min read

Point-symmetric Z purlin properties: A, Ix, Iy (approx), moduli, torsion and overlap note.

A
20.28 cm²
area
Ix / Sx
11.8/118
strong
Iy / Sy
0.36/10
weak adj.
J
0.02
torsion

Live statistics

Area

20.28 cm²

flanges + web

Ix / Sx

11.8 / 118

×10⁶mm⁴/cm³

Iy (adj.)

0.4 ×10⁶mm⁴

×0.85 stagger

Centroid

Mid-depth

point symmetric

Schematic only — not to scale. Dimensions follow the inputs below.

Unit system
Flange width B(mm) Help
mm

Each flange outstand.

Total depth H(mm) Help
mm

Overall depth.

Thickness t(mm) Help
mm

Uniform thickness.

Precision(decimals) Help
decimals

Decimals.

Precision
Results update live as you type

How you compare — standard sections

SectionDepth (mm)Mass (kg/m)A (cm²)Iₓ (×10⁶ mm⁴)Sₓ (×10³ mm³)
UB 305×165×40 · Steel I-beam 30440.351.385560
UB 457×191×67 · Steel I-beam 45467.185.52941290
UC 254×254×73 · Steel column 25473.193.1114895
RC 300×500 (C30) · Concrete beam 5003751500312512500
Glulam 140×450 · Timber beam 4502963010634725
SHS 200×200×8 · Hollow section 20047.460.436.9369

Indicative values for scheme design only. Always verify against the manufacturer / code tables (AISC Steel Manual, SCI Blue Book, ACI detailing) before ordering steel or pouring concrete.

Plans & details

Geometry

Section sketch

Dimensioned cross-section with centroid and axes. Verify b/h/t against drawings before issuing.

Detail

Bar layout / rolling

For RC: cover, bar positions and crack basis. For steel: rolling direction and weld access.

Nett

Connection zones

Holes, copes and welds deduct from gross — use nett properties at connections.

Typical details for scheme design. Replace placeholders with project drawings (1200×630 JPG or SVG line work in /public/plans/civil/). Do not scale from web images — use figured dimensions.

Design verification checklist

Work through before issuing results — 1/6 verified (17%).

Results

Normal

Area

20.28cm²

Flanges + web (overlap corrected)

Ix (strong)

11.8×10⁶ mm⁴

About major axis

Sx

117.9cm³

Ix/(H/2)

Iy (stagger-adjusted)

0.361×10⁶ mm⁴

I-value × 0.85 for opposite flanges (approx)

Torsion J

0.024×10⁶ mm⁴

Σbt³/3

Visualizations

Z-section Ix

11.8 ×10⁶mm⁴Ix

Formula

Z purlins mirror the I in strength but stagger flanges: strong axis matches, weak axis softens slightly (0.85 factor, scheme).

A, Ix as I (symmetric) | Iy ≈ 0.85 × I-value (flange stagger) | Sx = Ix/(H/2)

Alternative Form

Centroid at mid-depth by point symmetry · Lapped/nested purlins gain continuity — see system notes

Variables

SymbolNameUnitDescription
AAreacm²Steel area.
Ix / SxStrongmm⁴ / mm³Rafter-direction bending.
Iy / SyWeak (adj.)mm⁴ / mm³Stagger-reduced — brace it.
JTorsionmm⁴Open strips.

Explanation

Ix like an I, Iy × 0.85 for stagger, centroid centred by symmetry — Z strength with C-like lateral manners.

Derivation

Point symmetry centres the centroid; Ix integrates as an I. Flange stagger offsets Iy mass from the centroidal plane — 0.85 approximates the loss (verify lipped/coated tables).

Step-by-Step Calculation

Follow each step to understand how the result is calculated from your inputs.

Step 1

Enter flange B, depth H, thickness t

Result: Z fixed
Step 2

Read area

Result: Weight rate
Step 3

Read Ix/Sx (I-like)

Result: Strong done
Step 4

Read adjusted Iy (0.85)

Result: Weak flagged
Step 5

Brace at purlin/rail spacing

Result: Stability set
Step 6

Verify lipped tables for order

Result: Tables checked
Final Answer
20.28

Worked Examples

See how the calculator works with different scenarios.

Scenario

Purlin scheme.

Inputs

B:75 mm
H:200 mm
t:6 mm

Calculation

A ≈ 2·450 + 1128 = 2028 mm² = 20.3 cm². Ix ≈ 11.5e6. Iy(adj) ≈ 0.85·0.42e6 ≈ 0.36e6.

Result

Ix ≈ 11.5 ×10⁶, Iy ≈ 0.36 ×10⁶

Interpretation

Strong for span, soft sideways — sag rods and bridging do the lateral work.

Understanding Your Result

Your Result: Area = 20.28 cm² · Ix (strong) = 11.8 ×10⁶ mm⁴ · Sx = 117.9 cm³

Typical range: Z200×75×6-ish: ~20 cm², Ix ~11×10⁶, Iy(adj) ~0.4×10⁶; brace every 1.5–3 m.

What This Means

Purlin-ready Z geometry with the stagger-adjusted weak axis — span strength plus lateral honesty.

Why It Matters

Purlins fail sideways and at laps, not midspan. The adjusted Iy and lap notes prevent both.

Professional Interpretation

Confirm lipped/coated manufacturer tables for orders; detail laps, sag rods and eave/ridge restraints on the same sheet.

Recommendations

  • •Verify dimensions against the drawing before issuing properties
  • •Use gross properties for analysis; cracked/nett for checks as codes require
  • •Compare required S/I against the standard-section table below

Learn — structural behaviour, deeply

The overlapping purlin.

1 · The two equations that run every site

ΣF_y = 0

Vertical balance

Upward reactions must equal total downward load. Missing 1 kN here means a 1 kN shear error everywhere downstream.

ΣM = 0

Moment balance

Moments about ANY point must cancel. Take moments about one support to eliminate it and solve the other directly.

ΣF_x = 0

Horizontal balance

Zero for vertical-only loading — but the pin still needs checking once wind, soil or inclined loads appear.

Worked derivation (simply supported, point load): ΣMleft = 0 ⇒ Rb·L − P·a = 0 ⇒ Rb = P·a/L, then ΣFy = 0 ⇒ Ra = P − Rb = P·(L−a)/L. UDL adds w·L/2 per side acting at midspan. That is the entire calculation — everything else is bookkeeping.

2 · Support types — what each one can (and cannot) do

SupportReactionsAllowsWatch out
Roller1 (vertical)Horizontal slide + rotationProvides NO lateral restraint — pair with a pin or bracing.
Pin / hinge2 (vertical + horizontal)Rotation onlyMoment released here — detail the hinge, never weld it rigid by accident.
Fixed / clamped3 (+ moment)Nothing (fully restrained)Attracts large moments; settlement or temperature causes locked-in stress.
Propped cantilever3 (indeterminate ×1)Rotation at propNeeds compatibility (deflection = 0 at prop) — equilibrium alone is not enough.
Continuous (3+ supports)4+ (indeterminate)Rotation over interior piersSolve by superposition / moment distribution / software; reactions shift with stiffness.

3 · Factor-impact table — what moves your reactions most

FactorTypical impactWhy
Load position (a/L)Linear, dominantMoving P toward a support shifts ~100% of P onto it. Ra = P·(L−a)/L — position matters more than span.
UDL intensity (w)∝ w·L totalEach extra 1 kN/m on a 6 m beam adds 3 kN per reaction. Self-weight alone is often 1–5 kN/m on concrete.
Span length (L)∝ L for UDLDoubling L doubles UDL reactions and quadruples UDL moment (wL²/8). Keep spans tight where possible.
Overhang length (c)∝ c/L upliftUplift at the far support = P·c/L. A 2 m overhang with 10 kN on a 5 m span pulls down 4 kN — needs hold-down.
Fixity (pinned → fixed)Redistributes ~10–30%Fixed ends attract moment and shed midspan moment. Never assume fixity you have not detailed.
Support settlement (Δ)0 (det.) / large (indet.)Determinate beams just rotate; continuous/fixed beams develop locked-in moments ≈ 3EIΔ/L².
Dynamic / impact+10–100%Static reactions must be amplified for cranes, machinery, footfall (see ASCE 7 Ch. 4, AISC DG11).
Load combination× 1.2–1.6 (LRFD)1.2D + 1.6L + 0.5(Lr/S/R) governs most beams. Reactions for strength ≠ reactions for service checks.

4 · Code provisions you must cite on drawings

  • ASCE 7 load combinations (LRFD): 1.4D · 1.2D + 1.6L + 0.5(Lr/S/R) · 1.2D + 1.0W + 1.0L … Strength reactions use factored loads; bearing/deflection checks use service (unfactored) loads.
  • ACI 318 (concrete): strength-reduction ϕ = 0.65–0.90; development/lap lengths Ch. 25; one-way shear + punching Ch. 22. Reactions feed directly into Vu ≤ ϕVn.
  • AISC 360 (steel): Ch. F/G/H for moment/shear/combined; bearing at supports per J7–J8; bracing per App. 6. Connection must develop the computed reaction — a beam is only as strong as its seat.
  • Eurocode basis (EN 1990): ULS 1.35G + 1.5Q; SLS G + Q (characteristic). National annexes adjust factors — confirm the project annex.
  • Serviceability (all codes): live-load deflection ≈ L/360 floors, L/240 roofs; total ≈ L/240. Vibration: AISC DG11 / SCI P354 for rhythmic or office floors.

5 · Pro workflow (5 minutes per beam)

  1. Sketch the free-body diagram: every load incl. self-weight, every support, dimensions.
  2. Solve ΣM then ΣF — write both lines on the calc sheet so a checker can follow.
  3. Verify: re-take moments about the OTHER support; residual must be ≈ 0.
  4. Draw shear then moment (reactions are the SFD starting values).
  5. Size the support: bearing stress, padstone, bolt/weld group, foundation pressure.
  6. File: keep the input → reaction → SFD/BMD → support chain on one page.

6 · Field traps (where reactions go wrong)

  • • Forgetting self-weight: a 300×600 concrete beam weighs 4.5 kN/m — on 6 m that is 13.5 kN per support.
  • • Assuming fixity: a “fixed” sketch with two bolts is a pin. Model what you detail.
  • • Ignoring uplift: overhang + wind can reverse a bearing — light roofs lift off.
  • • Mixing factored/service: never compare a factored reaction against an allowable soil pressure.
  • • Point load at the wrong station: 0.5 m error on a 10 kN load swings reactions by P·Δa/L.

7 · The 3-check rule (sign-off standard)

  1. Math check: ΣFy and ΣM both close to zero with project units printed.
  2. Sanity check: reactions sum to total load; heavier side sits under heavier load; UDL symmetry gives Ra ≈ Rb.
  3. Load-path check: every reaction lands on something sized for it — beam → seat → column → footing → soil, no floating numbers.

Practical Tips

  • •Depth beats width: I ∝ h³, S ∝ h², A ∝ h — deepen before widening
  • •State the basis: gross, nett, cracked or transformed
  • •Cross-check S_req = M/σ against the table below

Common Mistakes

Mixing mm and cm in one calc
Enter all dims in the selected unit; the solver converts once internally.
Using gross I for RC deflection
Use cracked Ie plus creep for service deflection.
Ignoring fillets then ordering tight
Fillets add 1–3%: fine for scheme, verify against mill tables for order.

Assumptions

This calculator makes the following assumptions to provide estimates:

Sharp-corner idealisation: Fillets, welds and chamfers ignored (1–3% on area, less on I for scheme).
Prismatic section: Properties constant along the member length.
Homogeneous elastic material: Single E unless a modular ratio n is entered.

Limitations

Be aware of these limitations when using this calculator:

Gross elastic properties: Nett (holes) and cracked/transformed variants need their own deductions.
Thin-wall torsion approx.: Open-section J ≈ Σbt³/3; warping Cw per standard approximations.

Frequently Asked Questions

Answers to common questions about this calculator.

Z vs C purlins?
Z laps/nests over supports for continuity (less deflection, more capacity); C stacks for transport. Strength per kilo is close — system detailing decides.
Why 0.85 on Iy?
Opposite flanges sit on opposite sides of the web, slightly reducing weak-axis inertia vs a centred I. Scheme factor — manufacturer tables rule.
Lipped vs plain?
Lips (returns) add little Ix but lots of Iy and buckling strength. This plain model is conservative for lipped sections.
Which axis spans?
Strong Ix along the slope (gravity); weak Iy across (wind, lateral). Brace the weak at sag-rod spacing.
Do Zs twist?
Open, shear-centre offset like channels — restrain twist at laps, eaves and ridges.
Can I nest different depths?
No — laps need identical (or sleeved) depths. Mixing breaks bearing and bolt lines.
What is section modulus and how do I use it?
S = I/c (mm³): the geometric bending efficiency of a section. Bending stress = M/S; required S = factored moment / allowable (or design) stress. Compare against the standard-section table on each page.
How do I quickly check a steel beam?
Three checks per AISC 360: bending (Ch. F incl. lateral-torsional buckling over the unbraced length), shear (Ch. G), and deflection (L/360). Then verify the connection develops the end reaction.
How do I quickly check a concrete beam?
Flexure per ACI 318: ϕMn = ϕ·As·fy·(d − a/2) with ϕ = 0.9 (tension-controlled); one-way shear Vc + Vs (Ch. 22); deflection via minimum thickness or direct computation with cracked stiffness and long-term multiplier.
Shear vs bending moment — which sizes what?
Shear sizes stirrups/webs and connections (V ≤ ϕVn); bending moment sizes flexural steel and the section (M ≤ ϕMn via section modulus S: stress = M/S). Deflection is governed by stiffness EI, a third independent check.
Where does the maximum moment occur?
Where shear crosses zero: under a midspan point load, or at x = R/w under UDL (span moment = R·x − w·x²/2). On continuous beams also check the hogging peaks OVER interior supports — they often govern.
How do I convert kN ↔ kips and m ↔ ft?
1 kN = 0.2248 kips (1 kip = 4.448 kN); 1 m = 3.2808 ft. Moments: 1 kN·m = 0.7376 kip·ft. Every calculator on this site has an SI/Imperial toggle that converts all displayed values.
Which codes do these calculators follow?
Workflows cite ACI 318 (concrete), AISC 360 (steel), ASCE 7 (loads + combinations), IBC (deflection, occupancy loads) and Eurocode equivalents. Always confirm the edition and annex your project is permitted under.
How accurate are these calculators?
Scheme-stage accuracy from closed-form statics with stated assumptions (rigid supports, prismatic sections, static loads). Use them for sizing, checking and tender estimates — final permit/shop drawings need a licensed engineer and project-specific analysis.
Can I print, copy or share results?
Yes — every page has print, copy-link and share actions in the hero banner, and results render in a printable dashboard. Paste the equilibrium line (ΣR vs total load) onto your calc sheet as the proof.
Do I still need a structural engineer?
For anything that gets built: yes. Software and calculators don’t carry liability, don’t visit site, and don’t know your soil, wind exposure or buildability constraints. Use these tools to brief and check your engineer, not replace them.
What is development length and why does it matter?
The embedment needed for a bar to reach yield (ld, ACI 318 Ch. 25). A perfectly computed moment capacity is worthless if the bar pulls out — extend bars past inflection points and hook or develop them at supports.
How do I check bearing stress under a support?
Bearing stress = reaction / (bearing length × width) ≤ allowable (masonry ≈ 0.25–0.4·f′m, concrete per ACI 22.8, steel per AISC J8). If it fails, lengthen the bearing or add a padstone/spreader plate.
What deflection limits apply to beams?
Typical code limits: live-load deflection L/360 for floors (L/240 roofs), total-load L/240, cantilevers 2L/360-ish per IBC Table 1604.3. Always check under SERVICE loads with the correct (cracked, long-term) stiffness.
LRFD vs ASD — does it change the reactions?
No — equilibrium is the same. The design PHILOSOPHY differs: LRFD factors loads up (1.2D+1.6L) against factored resistance (ϕRn); ASD keeps service loads against allowable stresses (Rn/Ω). Keep the two systems in separate columns.
Which load combination usually governs a beam?
For strength: 1.2D + 1.6L (+ 0.5 for roof live/snow/rain) per ASCE 7 LRFD. Service D+L governs deflection and bearings; 0.9D + 1.0W governs uplift and overturning.
Service vs factored loads — which do I report?
Report BOTH in separate columns: service (unfactored D+L) for deflection, bearing, settlement and soil checks; factored LRFD (1.2D + 1.6L) for member strength. Never compare a factored reaction with an allowable soil pressure.
Pin, roller or fixed — how do I choose the support model?
Model what you DETAIL. Masonry/steel seats and two-bolt end plates are pins (moment released); moment frames, welded rigid joints and well-anchored cantilevers earn fixity. When in doubt, the pinned assumption is conservative for midspan moment but NOT for uplift.
Hold-down or bigger pad — which fixes uplift?
Only a hold-down (strap, anchor, dead weight) fixes uplift — a bigger pad just spreads a force acting the wrong way. Size the anchor for net factored uplift (0.9D + 1.0W) with proper embedment.
How does wind create uplift on beams and roofs?
Suction on leeward slopes/overhangs pulls upward; the net combination 0.9D + 1.0W (ASCE 7) often reverses light end reactions. Run it explicitly — gravity-only models hide the governing hold-down case.
How do I allow for impact and vibration?
Amplify static reactions per ASCE 7 Ch. 4 (cranes, machinery, forklifts: +10–100%) and check footfall vibration with AISC DG11/SCI P354 on office, gym and lab floors. These calculators report static values — apply the factors yourself.
How do I find reactions for a simply supported beam?
Take moments about the left support: Rb = (P·a + w·L·L/2) / L, then Ra = P + w·L − Rb. Always re-check by taking moments about the right support — the residual must be ≈ 0.
What does a negative (downward) reaction mean?
The support must pull DOWN instead of pushing up — net uplift from overhangs, pattern loading or wind. Provide a hold-down strap, anchor or ballast; a gravity-only bearing will lift off.
Do I include the beam self-weight?
Yes, always. A 300×600 mm concrete beam weighs ~4.5 kN/m — on a 6 m span that adds ~13.5 kN per support. Bundle it into the UDL before solving.
What is the difference between a UDL and a UVL?
A UDL (uniformly distributed load) is constant intensity over a length (kN/m). A UVL (uniformly varying / triangular) runs zero-to-max — e.g. soil or hydrostatic pressure. They integrate differently, so use the matching calculator.
How do I turn a floor area load into a beam line load?
Multiply the area load (kN/m²) by the tributary width (m) draining to the beam: line load = area load × tributary width. Add the beam self-weight, partitions and finishes first.

Related Calculators

Explore more calculators related to this topic.

Glossary

Technical terms used in mortgage calculations explained in plain language.

Reaction
Force (or moment) a support exerts on a member to maintain static equilibrium (ΣF = 0, ΣM = 0).
Simply supported
Beam on one pin + one roller. Resists vertical load; allows rotation and (at roller) horizontal movement.
Fixed support
Clamped end resisting force AND moment; prevents rotation. Used in cantilevers and fixed frames.
UDL / UVL
Uniformly distributed load (constant kN/m) vs. uniformly varying load (triangular, zero-to-max).
Tributary area
Floor/roof area whose load drains to one member. Line load = area load × tributary width.
Factored load
Service load × LRFD load factor (e.g. 1.2D + 1.6L) for strength design per ASCE 7.
Serviceability
Deflection, cracking and vibration limits under day-to-day (unfactored) loads.
Uplift
Net downward-hold requirement: a negative (downward-pulling) reaction, common on overhangs.

Authoritative References

Trusted sources and standards referenced by this calculator.

Applicable Standards

ACI 318 — Building Code Requirements for Structural ConcreteAISC 360 — Specification for Structural Steel BuildingsASCE 7 — Minimum Design Loads and Associated CriteriaEurocode 2 (EN 1992) — Design of Concrete StructuresEurocode 3 (EN 1993) — Design of Steel StructuresIBC — International Building Code (structural chapters 16–23)

Was This Calculator Helpful?

Page Information

Last Updated:

2026-09-28

Version:

2.0.0

License:

Free to use for educational and professional purposes.